Voltage-controlled voltage isol setup, Activating isol programming voltage mode, Deactivating isol voltage mode – Xantrex Technology XTR 850 Watt User Manual

Page 114: Query for isol voltage input level, Voltage-controlled voltage isol setup –22

Advertising
background image

Analog Programming (APG) and Isolated Analog Programming (ISOL)

4-22

975-0200-01-01

Voltage-Controlled Voltage ISOL Setup

Activating ISOL Programming Voltage Mode

To activate ISOL programming voltage mode with an external
voltage source:

1. Turn the mode control knob to the VAP position or press the Rotary

knob/Enter button if the control knob is already at the VAP position.
WAPr is displayed on the output voltage display.

2. Turn Rotary knob/Enter button to select U IS (voltage source from

isolated connector).

3. Press the Rotary knob/Enter button to commit the selected mode.

LE U is displayed on the output voltage display.

4. Select the input source level using the Rotary knob/Enter button.

5. Once the desired level has been selected, press the Rotary knob/

Enter button to commit the change.

The display will return to the normal display.

Deactivating ISOL Voltage Mode

To deactivate the ISOL voltage mode:

1. Turn the mode control knob to the VAP position or press the Rotary

knob/Enter button if the control knob is already at the VAP position.

2. UAPr is displayed on the output voltage display.

3. Turn the Rotary knob/Enter button to select nonE.

4. Press the Rotary knob/Enter button to commit the change.

The display will return to the normal display.

Query for ISOL Voltage Input Level

To query for ISOL voltage input level from non-isolated input:

1. Turn the mode control knob to the VAP position or press the Rotary

knob/Enter button if the control knob is already at the VAP position.
UAPr is displayed on the output voltage display.

Advertising