Electrical specifications for xtr 1700 watt, Table c-2 – Xantrex Technology XTR 850 Watt User Manual

Page 254

Advertising
background image

C-4

975-0200-01-01

Speci

fications

Electrical Specifications for XTR 1700 Watt

Table C-2 XTR 1700 Watt Electrical Specifications for 6 V to 600 V Models

Models

6-220

8-200

12-140

20-84

33-50

40-42

60-28

80-21

100-17

150-11.2

300-5.6

600-2.8

Output Ratings:

Output Voltage

1

Output Current

2

Output Power

3

1.Minimum voltage is guaranteed to maximum 0.2% of the rated output voltage.
2.Minimum current is guaranteed to maximum 0.4% of the rated output current.
3.Total output power is also based on AUX1 Output Voltage (5 V) and AUX1 Output Current (0.5 A) and AUX2 Output Voltage (15 V) and AUX2 Output Current (0.5 A).

6 V
220 A
1330 W

8 V
200 A
1610 W

12 V
140 A
1690 W

20 V
84 A
1690 W

33 V
50 A
1660 W

40 V
42 A
1690 W

60 V
28 A
1690 W

80 V
21 A
1690 W

100 V
17 A
1710 W

150 V
11.2 A
1690 W

300 V
5.6 A
1690 W

600 V
2.8 A
1690 W

Line Regulation:

Voltage

4

(0.005% of rated output

voltage +2 mV)

Current

5

(0.01% of rated output

current +2 mA)

2.3 mV

13 mA

2.4 mV

12 mA

2.6 mV

9 mA

3.0 mV

6.2 mA

3.7 mV

4.5 mA

4 mV

4.1 mA

5 mV

3.4 mA

6 mV

3.1 mA

7 mV

2.9 mA

9.5 mV

2.6 mA

17 mV

2.3 mA

32 mV

2.1 mA

Load Regulation

Voltage

6

(0.005% of rated output

voltage + 2 mV)

Current

7

(0.02% of rated output

current +5 mA

2.3 mV

49 mA

2.4 mV

45 mA

2.6 mV

33 mA

3.0 mV

22 mA

3.7 mV

15 mA

4 mV

13 mA

5 mV

10.6 mA

6 mV

9.21 mA

7 mV

8.4 mA

9.5 mV

7.2 mA

17 mV

6.1 mA

32 mV

5.6 mA

Output Ripple (rms, 300 kHz):

Voltage

Current

8

8 mV
200 mA

8 mV
180 mA

8 mV
120 mA

8 mV
75 mA

8 mV
60 mA

8 mV
45 mA

8 mV
35 mA

8 mV
25 mA

8 mV
20 mA

10 mV
16 mA

25 mV
10 mA

50 mV
6 mA

Output Ripple (p-p, 20 MHz):

Voltage

50 mV

50 mV

50 mV

50 mV

50 mV

50 mV

50 mV

80 mV

80 mV

100 mV

150 mV

250 mV

Maximum Recommended Remote Sense

Line Drop Compensation per Line

9

1 V

1 V

1 V

1.5 V

2 V

2 V

3 V

5 V

5 V

5 V

5 V

5 V

Up-prog. Response Time, 0~Vmax

10

60 ms

60 ms

60 ms

60 ms

60 ms

60 ms

60 ms

100 ms

100 ms

100 ms

150 ms

250 ms

Down-prog. Response Time: Full Load

50 ms

50 ms

50 ms

50 ms

50 ms

50 ms

50 ms

80 ms

100 ms

150 ms

150 ms

250 ms

Down-prog. Response Time: No Load

300 ms

400 ms

500 ms

600 ms

700 ms

800 ms

900 ms

1000 ms

1200 ms

1800 ms

2200 ms

3500 ms

Over-Voltage Trip Point

0.5–7.5 V

0.5–10V

1–15 V

1–24 V

2–39 V

2–44 V

3–66 V

3–95 V

3–125 V

3–180 V

5–330 V

5–660 V

Efficiency

11

76/78%

77/79%

81/84%

82/85%

83/86%

83/87%

84/88%

84/88%

84/88%

84/88%

84/88%

84/88%

Advertising