Configuring multiple supplies for series operation, Connecting to the load in local sensing mode, Figure 3-5 – Xantrex Technology XTR 850 Watt User Manual

Page 87: Series operation –39, Caution

Advertising
background image

Using Multiple Power Supplies

975-0200-01-01

3-39

3

Configuring Multiple Supplies for Series Operation

A maximum of two power supplies of the same rating can be connected in
series to increase the output voltage.

Connecting to the Load in Local Sensing Mode

Connect the negative (–) output terminal of one power supply to the
positive (+) output terminal of the next power supply. See Figure 3-5 for a
representation of series operation.

CAUTION

When two power supplies are connected in series, they should be programmed to
the same output voltage to prevent damage to the lower voltage supply at short
circuit condition.

Figure 3-5 Series Operation

J1.1

+S

+

J1.6

-S

+

J1.5

-LS

J1.2

+LS

J1.6

-S

J1.1

+S

+

LOAD

J1.5

-LS

J1.2

+LS

Power Supply

Power Supply

Advertising