Multiple Power Supply Connections to RS-485 Bus

Up to 30 units may be connected to the RS-485 bus. The first unit (master
unit) connects to the controller via any appropriate port, and the other
units (slave units) are connected with the RS-485 bus via the J6
connector. All units connected together should also have unique
multichannel addresses.

A standard straight-through RJ-45 ethernet network cable can be used to
provide the connection between the power supplies. See Figure 5-14.

Multiple Power Supply Setup

Master Setup:

u Configure the master XTR by selecting the communication interface

you wish to use to communication with the Master and follow the
setup instruction in this chapter.

Slave Setup:

1. Turn the mode control knob to PGM.

rE is displayed in the output voltage display.

Figure 5-14 Multi Power Supply Connection to RS-485 Bus

Note:

If either RS-232 or RS-485 are used for communication with the

master, the data rate must be configured for 9600 bps to properly communicate
with the slave units.