Using Multiple Power Supplies

975-0200-01-01

3-43

3

Connecting to the Load in Local Sensing Mode (Parallel Control
Method)

Connect the power supplies in parallel to obtain a single output supply
with a higher output current set point. Set all of the outputs to the same
voltage before connecting the positive (+) and negative (–) terminals in
parallel. The total current available is the sum of the maximum currents of
each power supply.

Figure 3-7 Load Connections in Local Sensing Mode