Execution error list, Table b-2 – Xantrex Technology XTR 850 Watt User Manual

Page 247

Advertising
background image

Error Messages

975-0200-01-01

B-3

B

Execution Error List

An error in the range [-299, -200] indicates that an error has been detected
by the instrument’s execution control block. The occurrence of any error
in the class causes the execution error bit (bit 4) in the Event Status
Register to be set.

Execution errors are reported by the device after rounding and expression
evaluation operations have taken place.

Table B-2 Execution Error List

Error Code Error Message Description

-203

Command protected
Indicates that a legal password-protected program command or
query could not be executed because the command was
disabled. Check calibration state.

-220

Parameter error
Indicates that a program data element related error occurred

-221

Setting conflict
Indicates that a legal program data element was parsed but
could not be executed due to the current power supply state.

Factors that may contribute to this error are:

Remote source - To set most values, the remote source must be
correct.

Remote state - To set most values, the unit must be in remote
mode.
Calibration mode - when in calibration mode, certain settings
will cause as error.
Current share mode - When the unit is in current share mode
(other than none) certain settings will cause an error.

-240

Hardware error (occurs during flash update if there is a failure)
Indicates that a legal program command or query could not be
executed because of a hardware problem in the power supply.

-241

Hardware missing
Indicates that a legal program command or query could not be
executed because of missing power supply hardware; e.g. an
option not installed.

-282

Illegal program name
The name used to reference an auto sequence program was
invalid or there is no program selected.

Advertising