Clearing alarms, Clearing triggered and manual alarms, Clearing a flash failure alarm – Xantrex Technology XTR 850 Watt User Manual

Page 66: Clearing alarms –18

Advertising
background image

Local Operation

3-18

975-0200-01-01

Clearing Alarms

Clearing Triggered and Manual Alarms

To clear a triggered alarm, use one of the following methods:

• Turn the power supply Off and then On.

• Press and hold the Rotary knob/Enter button for 3 seconds.

• Press the reset key combination (Flash Fail ONLY). See “Resetting the
Power Supply” on page 3–35
.

To clear a manual alarm:

1. Press the Rotary knob/Enter button for 3 seconds.

The Alr Clr message will be displayed on the front panel for a few
seconds.

2. Repeat the alarm clearing until you have cleared all alarms.

Clearing a Flash Failure Alarm

The Flash Failure alarm is the only exception for clearing alarms. Flash
failure can only be cleared by a reset (see “Resetting the Power Supply”
on page 3–35) or b
y power cycling the unit.

To clear a triggered alarm, use one of the following methods:

Turn the power supply Off and then On.

Press and hold the Rotary knob/Enter button for 3 seconds.

Press the reset key combination (Flash Fail ONLY). See “Resetting
the Power Supply” on page 3–35.

The SCPI command (s) for these instructions are:

[:]OUTPut[<channel>]:PROTection:CLEar

Important:

When an alarm is cleared by using this method, only the current

highest precedence alarm is cleared. If another alarm has occurred, then this
alarm will not become the highest precedence alarm and will begin blinking on
the display.

Advertising