Remote operation, Table c-3 – Xantrex Technology XTR 850 Watt User Manual

Page 256

Advertising
background image

C-6

975-0200-01-01

Speci

fications

Remote Operation

Table C-3 Remote Operation

Programming Mode

APG

ISOL

Digital

Voltage and Current Output Voltage Programming

0–100%, 2~ up to 10 V, programmable

Current Output Resistor Programming

0–100%, 2~ up to 10 k

Ω, programmable

Voltage Output Resistor Programming

0–100%, 2~ up to 10 k

Ω, programmable

Output Voltage and Current Monitor

0–100%, 2~ up to 10 V, programmable

Voltage Programming Accuracy (mV)

± 0.5% of rated output voltage

±0.1% of rated output voltage

Current Programming Accuracy (mA)

± 1% of rated output current

±0.2% of rated output current

Voltage Readback Accuracy (mV)

± 1% of rated output voltage

±0.1% of rated output voltage

Current Readback Accuracy (mA)

± 1% of rated output current

±0.2% of rated output current

Isolation (Prog and Readback Lines)

With respect to chassis potential:
500 V

With respect to:
chassis potential: 500 V.
negative or positive main output: 1500 V.
negative or positive auxiliary output:
300 V.

Voltage and Current Programming Resolution

0.012% of full scale

Voltage and Current Readback Resolution

Parallel Operation

Up to 4 units in master/slave
mode

Series Operation

Up to 2 units (with external
diodes)

Constant Voltage (CV)/Constant Current (CC) Indicator

CV: TTL High (4–5 V)
CC: TTL Low (0–0.6 V)

Advertising