Dataproducts submenu, Data bit 8, Pi ignored – Printronix P7000 Cartridge Ribbon Printer User Manual

Page 95: Data polarity

Advertising
background image

Dataproducts Submenu

95

Dataproducts Submenu

Data Bit 8

Enable

(default). Allows access to the extended ASCII character set.

Disable

. The printer interprets bit 8 of each incoming data character as a

zero, regardless of its actual setting.

PI Ignored

The PI (Paper Instruction) signal is used to control vertical paper motion.

Enable

(default). Causes the printer to interpret the eight data lines as

DVFU commands when the PI signal is true.

Disable

. Ignores the PI signal and treats the data as characters or control

codes.

Data Polarity

The Data Polarity parameter must be set to match the data polarity of your
host computer.

Standard

(default). Does not expect the host computer to invert the data.

Inverted

. Expects the data received on the data lines from the host

computer to be inverted. Ones become zeros, and zeros become ones.

Dataproducts

(from page 87)

Data Bit 8

PI Ignored

Data

Polarity

Resp.

Polarity

Latch Data

On

Prime Signal

TOF Action

Buffer Size

in K

1

Enable*

Disable

Enable*

Disable

Standard*

Inverted

Standard*

Inverted

Middle*

Trailing

Leading

Disable*

Enable

Reset*

Do Nothing

16*

(1-16)

* = Factory Default

1

OpenPrint HD products have an extended range to 256.

Auto

Trickle

Disable*

Enable

Trickle

Time

1/4 sec*

1/2 sec

1 sec

2 sec

4 sec

8 sec

16 sec

Off

Advertising