SENA ProBee-ZE10 User Manual

Page 30

Advertising
background image

30

ProBee-ZE10 User Guide Rev.1.5

ATS55=n, where n is rejoin timeout and the default is 10.

When the connection to the parent node is broken for S55 in seconds, the child node tries to rejoin the

current network.

Figure 3-1 Sleep Interval and Wake-up Timing

The sleepy end-device can also wake up from the sleep mode by GPIO0 interrupt or incoming serial data.

Once it wakes up, it also polls with the parent node at S52 interval and goes into sleep mode after S54

time elapses after the last data exchange.

Note: If the sleepy end-device wakes up by incoming serial data, the integrity of the first incoming byte is

not guaranteed. It is strongly recommended to wake up the sleepy end-device by using GPIO0 first before

sending the serial data or use higher level serial data protocol to check the data integrity.

3.5

ZigBee Security

Security is a major concern in the ZigBee architecture. Although ZigBee uses the basic security elements

in IEEE 802.15.4 (e.g., AES encryption & CCM security modes), the ZE10 increases the security level

with:

128 bit AES encryption algorithms

Strong, NIST-approved security

Defined Key Types (Link, Network)

Defined Key setup and maintenance

Poll Request

Data Exchange

Parent Node

Sleepy End-Device

Sleep

Wake-Up

Sleep

S53

S52

S54

Advertising