SENA ProBee-ZE10 User Manual

Page 60

Advertising
background image

60

ProBee-ZE10 User Guide Rev.1.5

OK

# Response

AT+REMOTE=9AD6,AT+AI?

# Get all the analog data of Router from remote coordinator

****,****,218F,0D9A

# Analog data of Router

OK

# Response

AT+REMOTE=0001950000000212,AT+AI2?

# Get router’s analog data for temperature from remote coordinator

218F

# Router’s analog data for temperature (Refer to 6.6.7 Data

# Conversion)

OK

# Response

AT+REMOTE=9AD6,AT+AI3?

# Get router’s analog data for illumination from remote coordinator

0D8D

# Router’s analog data for illumination (Refer to 6.6.7 Data

# Conversion)

OK

# Response

6.6.5

Periodic Sampling – Destination Node

6.6.5.1 Coordinator Configuration

The AT commands for Coordinator Configuration:

ATS11=1

# Set coordinator to receive incoming data

OK

# Response

ATZ

# Apply configuration

OK

# Response

6.6.5.2 Router Configuration

The AT commands for Router Configuration:

AT+DESTLA=0001950000001481

# Set coordinator to the destination device to send

# analog data such as temperature, illumination

OK

ATS42=1

# Period to send analog data to destination (unit : second)

OK

# Response

ATS43=0

# Set destination to AT+DESTLA

# ATS43=1 sets destination to sink node

ATZ

# Apply configuration

OK

# Response

Advertising