One ZE10 module acts as a sleepy end-device and it sends temperature sensor, light sensor and
digital inputs to the coordinator every second.
Figure 6-3 Example #1: 1 Coordinator, 1 Router and 1 End-Device
6.4.1
Coordinator Configuration
Hardware configuration for the coordinator is as follows:
Set the HOST switch to USB
Close the USB_PWR jumper and open the RS_PWR and BATT_PWR jumpers.
Connect a USB cable between a host computer and the coordinator
The AT commands for the coordinator are as follows:
AT+NODETYPE=1
OK
AT+PANID=7772
OK
ATS11=1
OK
AT+LONGADDR
0001950000000001
OK
ATZ
OK
6.4.2
Router Configuration
Hardware configuration for the coordinator is as follows:
Set the ADC_2 and ADC_3 switch to TEMP_SENS and LIGHT_SENS
The AT commands for the router are as follows:
AT+NODETYPE=2