Range

00001000 - 03FFF000

7.4.2

AT+PANID or AT+PI

Description

Get/Set the 16-bit PAN ID. If it is set to 0s at a coordinator, the coordinator will select a

random 16-bit hexadecimal number as PAN ID. If it is set to 0s at a router/end-device,

the router/end-device will try to join any existing network regardless of PAN ID.

Execute

AT+PANID?<CR>

AT+PANID=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

0000

Range

0000 – FFFF

7.4.3

AT+EPID or AT+EI

Description

Get/Set the 64-bit extended PAN ID. If the node is a coordinator and the EPID is set to

0s, it will create new extended PAN ID using its 64-bit IEEE address as extended PAN

ID. If the node is a router or end-device and the EPID is set to 0x, it will try to join any

existing network regardless of extended PAN ID.

Execute

AT+EPID?<CR>

AT+EPID=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

0000000000000000

Range

0000000000000000 - FFFFFFFFFFFFFFFF

7.4.4

AT+GROUPID or AT+GI

Description

Get/Set the 16-bit Group ID. It is used for multicast data reception.

Execute

AT+GROUPID?<CR>

AT+GROUPID=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

0000

Range

0000 - FFFF

7.4.5

AT+POWER or AT+PW

Description

Get/Set the TX power at which the RF module transmits conducted power.

Execute

AT+POWER?<CR>

AT+POWER=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

3

Range

-43 - 3