SENA ProBee-ZE10 User Manual
Page 81
81
ProBee-ZE10 User Guide Rev.1.5
AT+LINKKEY=5A46…21<CR>
# set the 128-bit trust center link key (5A46…21)
ATZ<CR>
# Apply the change
OK
# Response
AT+NWKKEY=0<CR>
# set the 128-bit network key (random key)
OK
# Response
AT+UPDATEKEY<CR>
# update the changed network key
OK
# Response
8.4
UART Settings
AT+BAUDRATE=115200<CR>
# set baud rate (115,200bps)
OK
# Response
AT+DATABIT=8<CR>
# set data bit (8bit)
OK
# Response
AT+PARITY=0<CR>
# set parity (none)
OK
# Response
AT+STOPBIT=1<CR>
# set stop bit (1bit)
OK
# Response
AT+FLOWCTRL=2<CR>
# set flow control (hardware)
OK
# Response
ATZ<CR>
# Apply the change
OK
# Response
8.5
GPIO
AT+GPIO=5500044112233<CR>
# set GPIO configuration
OK
# Response
ATZ<CR>
# Apply the change
OK
# Response
AT+GPIO0<CR>
# check the current GPIO status (GPIO0)
5
OK
# Response
AT+DIO<CR>
# check the current DIO value
10000**000011
OK
# Response
AT+AI<CR>
# check the current AI value
****,****,2EE0,2EE0
OK
# Response