SENA ProBee-ZE10 User Manual

Page 86

Advertising
background image

86

ProBee-ZE10 User Guide Rev.1.5

application can tolerate in broadcast/multicast data transmission.)

Execute

ATS32?<CR>

ATS32=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR>

Default

5

Range

0 – 99

9.3.3

S33

Description

Get/Set the transmission timeout in milliseconds. A sender retransmits data packet

after this time when transmission fails. (CAUTION: It is recommended to set this value

more than 1000 in broadcast/multicast data transmission.)

Execute

ATS33?<CR>

ATS33=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR>

Default

500

Range

0 – 10000

9.3.4

S34

Description

Get/Set the indirect transmission timeout in milliseconds. It is the maximum amount of

time that the MAC will hold a message for indirect transmission to a child.

Execute

ATS34?<CR>

ATS34=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR>

Default

3000

Range

0 – 30000

9.3.5

S35

Description

Get/Set the broadcast range. ZigBee specifies three different broadcast addresses that

reach different collections of nodes. Broadcasts are normally sent only to routers.

Broadcasts can also be forwarded to end-devices, either all of them or only those that

do not sleep. Broadcasting to sleepy end-devices is both significantly more resource-

intensive and significantly less reliable than broadcasting to routers.

0: send to all routers

1: send to all non-sleepy nodes

2: send to all nodes in the network

Execute

ATS35?<CR>

ATS35=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR>

Advertising