SENA ProBee-ZE10 User Manual

Page 72

Advertising
background image

72

ProBee-ZE10 User Guide Rev.1.5

7.7

Data Transmission and Reception

7.7.1

AT+DESTLA or AT+DL

Description

Get/Set the 64-bit destination IEEE address for unicast data transmission.

Execute

AT+DESTLA?<CR>

AT+DESTLA=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

0000000000000000

Range

0000000000000000 - FFFFFFFFFFFFFFFF

7.7.2

AT+DESTGROUPID or AT+DG

Description

Get/Set the 16-bit destination Group ID for multicast data transmission.

Execute

AT+DESTGROUPID?<CR>

AT+ DESTGROUPID=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

0000

Range

0000 – FFFF

7.7.3

AT+SINKINFO or AT+SI

Description

Get the long and short addresses of sink node. If there is no sink node in the network,

the addresses will be “FFFFFFFFFFFFFFFF” and “FFFF”.

Execute

AT+SINKINFO?<CR>

Response

<IEEE address>,<nodeID><CR>

OK<CR>

7.7.4

AT+MAXPAYLOAD or AT+MP

Description

Get the maximum size of the payload that the Application Support sub-layer will

accept. The size depends on the security level in use.

Execute

AT+MAXPAYLOAD?<CR>

Response

<value><CR>

OK<CR>

7.7.5

AT+TRASNSMITMODE or AT+TM

Description

Get/Set the data transmission mode. This mode is maintained after rebooting. (0:

none, 1: unicast to destination long address, 2: multicast to destination group ID, 3:

broadcast to all nodes, 4: unicast to sink node)

Execute

AT+TRANSMITMODE?<CR>

AT+TRANSMITMODE=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

0

Advertising