SENA ProBee-ZE10 User Manual

Page 74

Advertising
background image

74

ProBee-ZE10 User Guide Rev.1.5

Execute

AT+LINKKEY?<CR>

AT+LINKKEY=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF

7.8.3

AT+NWKKEY or AT+NK

Description

Get/Set the 128-bit network key. (0 or 0s: generate random 128-bit number)

Execute

AT+NWKKEY?<CR>

AT+NWKKEY=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF

7.8.4

AT+UPDATEKEY or AT+UK

Description

Update the network key with a new generated key. (possible only for coordinator) It is

applied after 30s later because sending too quickly may cause a sleepy end-device to

miss the alternate encryption key and only get the switch key message, which means it

will be unable to change to the new network key.

Execute

AT+UPDATEKEY<CR>

Response

OK<CR> or ERROR<CR>

7.9

UART

7.9.1

AT+BAUDRATE or AT+UB

Description

Get/Set the serial port speed for communication between the module serial port and

host.

Execute

AT+BAUDRATE?<CR>

AT+BAUDRATE=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

9600

Range

300 - 230400

7.9.2

AT+DATABIT or AT+UD

Description

Get/Set the serial data bit setting on the module.

Execute

AT+DATABIT?<CR>

AT+DATABIT=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

8

Range

7 - 8

Advertising