SENA ProBee-ZE10 User Manual

Page 82

Advertising
background image

82

ProBee-ZE10 User Guide Rev.1.5

8.6

Firmware Upload

8.6.1

Local Node

# enter the bootloader menu for uploading firmware. Note that UART of local
node should be set to 115200-8-N-1-N.

AT+BOOTLOAD<CR>

Press Enter…

EM250 Bootloader v20 b09

1. upload ebl

2. run

3. ebl info

BL >

# press “1” and upload ebl file by X-modem

begin upload

CCCCCCCCCCCCC

Serial upload complete

# press “2” or reset after upload is done

8.6.2

Remote Node

# upload firmware to a remote node using 64-bit long address. Note that UART
of local node should be set to 115200-8-N-1-N.

AT+BOOTLOAD=1,00019500002FDC40<CR>

Please start .ebl upload image ...

CCCCCCCCCCCCC

# upload ebl file by X-modem

Bootload Complete!

# succeed to upload

8.6.3

Clone

# clone the firmware of the local node to a remote node using 64-bit long
address. Note that UART of local node should be set to 115200-8-N-1-N.

AT+BOOTLOAD=2,00019500002FDC40<CR>

Start cloning ...

Bootload Complete!

# succeed to upload

Advertising