Firmware Upload
8.6.1
Local Node
# enter the bootloader menu for uploading firmware. Note that UART of local
node should be set to 115200-8-N-1-N.
AT+BOOTLOAD<CR>
Press Enter…
EM250 Bootloader v20 b09
1. upload ebl
2. run
3. ebl info
BL >
# press “1” and upload ebl file by X-modem
begin upload
CCCCCCCCCCCCC
Serial upload complete
# press “2” or reset after upload is done
8.6.2
Remote Node
# upload firmware to a remote node using 64-bit long address. Note that UART
of local node should be set to 115200-8-N-1-N.
AT+BOOTLOAD=1,00019500002FDC40<CR>
Please start .ebl upload image ...
CCCCCCCCCCCCC
# upload ebl file by X-modem
Bootload Complete!
# succeed to upload
8.6.3
Clone
# clone the firmware of the local node to a remote node using 64-bit long
address. Note that UART of local node should be set to 115200-8-N-1-N.
AT+BOOTLOAD=2,00019500002FDC40<CR>
Start cloning ...
Bootload Complete!
# succeed to upload