7at command reference – SENA ProBee-ZE10 User Manual

Page 64

Advertising
background image

64

ProBee-ZE10 User Guide Rev.1.5

7

AT Command Reference

7.1

Command Line Format

Each command line is composed of a prefix, body and terminator. Only “AT” can be used for the prefix.

The body is a string of characters. The terminator is <CR> or <NL>. A command can be one of the

followings:

Read a configuration parameter:

AT<Command>?<CR>

Do something:

AT<Command><CR>

Write a configuration parameter:

AT<Command>=<Parameter 1>,<Parameter 2>,<Parameter 3>,…<CR>

Commands denoted with a “+” character are extended AT commands.

S-registers are supported. Multiple commands in the same command line are not supported.

7.2

Standard AT Commands

7.2.1

AT

Description

Check the state of the connection between host and ProBee device.

Execute

AT<CR>

Response

OK<CR>

7.2.2

ATB

Description

Enter the broadcast data mode. Every data is packetized at intervals of inter character

timeout (S12) and transmit range is determined by broadcast range (S35).

Execute

ATB<CR>

Response

OK<CR>

7.2.3

ATD

Description

Enter the unicast data mode to specific node. If there’s no argument after the

command,

it

will

connect

to

the

preconfigured

destination

IEEE

address

(AT+DESTLA). Every data is packetized at intervals of inter character timeout (S12).

Execute

ATD<CR>

ATD<nodeID><CR>

ATD<IEEE><CR>

Response

OK<CR> or ERROR<CR>

Advertising