SENA Parani-MSP100 User Manual

Page 21

Advertising
background image

21

<Configuration of Server Mode>

Default Data Port

If unregistered device tries to connect to Parani-MSP100, Parani -MSP100 will assign the port

number consecutively from Default Data port.

KeepAlive Timeout

When TCP connection is stopped unexpectedly (Ex. Power off of Host PC), Parani-MSP100

will request NULL during KeepAlive Timeout (second). If there is no response during this

Timeout, TCP connection will be finished.

Do not disconnect TCP socket

In Server Mode, each TCP connection and Bluetooth connection will be matched as point-to-

point. When new Bluetooth connection is established, new TCP connection will be established

as well.

So, if Bluetooth connection is stopped, TCP connection can be finished.

To prevent this, users may use this option, so does not need to make TCP connection

whenever Bluetooth connection is stopped.

Register Bluetooth Device: Shows the Bluetooth devices registered.

Add: Add Bluetooth device to register.

Delete: Remove Bluetooth device registered.

Modify: Modify Port of the selected device.

B) Client Mode

In Client Mode, Parani-MSP100 will act as a TCP client. When a Bluetooth device connects to

Parani-MSP100, Parani-MSP100 will try to connect to the designated Host PC. So, Host PC

Advertising