22
should be in standby status.
In Client Mode, please select the IP address and port number of the Host PC to connect.
<Configuration of IP address of Host>
Select “Advanced Configuration” button.
Here, users may configure which Bluetooth device will connect to which Host, as they need.
Bluetooth device “00:0B:53:16:12:C7” will connect to Host “192.168.20.251”, port no. 5002.
Bluetooth device “00:0B:53:16:12:74” will connect to Host “192.168.20.252”, port no. 5004.
Bluetooth devices, which are not configured to connect to a specific Host, will connect to Default Host in
Host information.
<Configuration of Client Mode>
•
Host IP Address
For network Host Server IP address entry
•
Host Port Number
For Server Host port no. entry
•
Re-connect automatically if link is lost.