SENA Parani-MSP100 User Manual

Page 33

Advertising
background image

33

4.2.1. Parani-MSP100 Configuration

Basic Setting

(1) Bluetooth name: For user Parani-MSP100 name revision

(2) Maximum Connection: For configuring the maximum number of Bluetooth devices connectable

to Parani-MSP100.

Default maximum is 7.

(3) Discoverable: When checked, Parani-MSP100 is in INQUIRY mode, discovering in-range

Bluetooth devices.

(4) Connectable: When checked, Parani-MSP100 is in PAGE mode, connecting to Bluetooth

devices.

(5) Pairable: For Pairing mode enable/disable.

When in need of high security, set Pairable option

to UNCHECKED, enabling High Security.

When this option is NOT checked, other Bluetooth

devices, except those previously connected to Parani-MSP100, cannot connect to Parani-MSP100,

even via PIN code.

(6) Control port: For control port number entry.

Default value is 2525.

Buffering

(1) Buffering: For Buffering function enable/disable

* Firstly set Header and Trailer, secondly turn on Buffering option.

(2) Header: For buffer frame header entry.

Enter alphabet or HexaCode.

(3) Trailer: For buffer frame trailer entry.

Enter alphabet or HexaCode.

Security

Advertising