A.2. commands for server mode – SENA Parani-MSP100 User Manual
Page 41
41
USER <username>
:
To enter Log in Name
Ex.:
USER admin
+OK Password required
PASS <password> [new password]
:
To enter or change the Password for logging in.
Below Example shows how to change Password from ‘admin’to ‘1234’
Ex:
PASS admin
+OK User Authenticated
PASS admin 1234
+OK
QUIT
:
To quit the communication with Parani-MSP100
Ex.:
QUIT
+OK
Disconnected
MODE [server|client|vertex|hub|repeater|rs232]
:
To check or change the current Operation MODE of Parani-MSP100.
If any of Bluetooth devices are connected to Parani-MSP100, MODE
change is not allowed. Before changing the MODE, please drop all of
Bluetooth connections first.
Ex.:
MODE
+OK Server Mode
MODE CLIENT
+OK Client Mode
A.2. Commands for Server Mode
PORT [port no.]
:
To configure default data port number of Server Mode Parani-MSP100.
If a Bluetooth device, which is not pre-registered to Parani-MSP100, has
connected to Parani-MSP100, port number will be assigned automatically
by Parani-MSP100. Users may check the port numbers used by LIST
command.