54

as Inquiry scan and Page scan, then converts

the operation status to ‘Standby’

AT+SETESC

Escape sequence character set to ‘+’ by

default is changeable. The parameter nn must

be a printable character.

AT+SETESC,42

AT+BTLAST?

The Bluetooth device last connected to this

Parani-MSP100 is displayed with its BD

address.

AT+BTSEC

If the authentication is activated, the pin code

must be set by AT+BTKEY command. Data

encryption

cannot

be

used

when

authentication

is

not

enabled,

i.e.

Authentication=0 and Encryption=1 will not

work properly.

AT+BTSD?

Once a connection is made with a pin code,

Parani-MSP100 saves the Bluetooth device

with its link key, generated by the pin code.

The connection to a device listed in Parani-

MSP100 can be made automatically without

the authentication process. The maximum

number kept on the list is 5.

AT+BTCSD

This clears the list of Bluetooth devices linked

with the same key in flash memory. To take

effect the ATZ command must be used or

Powercycle the unit.

AT+BTMODE

When

the

operation

status

is

‘Pending’

currently, change the status to ‘Standby’ with

AT+BTCANCEL prior to this command.

To take effect the ATZ must be executed or

Powercycle the unit. Support only Mode 1 and

Mode 2. You can register Mode 1 devices by

using AT+BTREG.

S

※ -registers are not supported.

Following commands are appended to Parani-MSP100.

Command

Description

Example

AT+BTCHAN?

Show currently selected device.

AT+BTCHAN?

Advertising