SENA ProBee-ZE20S-SEME User Manual
Page 101
ProBee-ZE20S-SExx User Guide Rev 1.8
101
7.15.4 AT+SMFPENDTIME or AT+SFT
Description
Get/Set Metering Fast Poll Mode End Time. This value will be used in ‘Request
Fast Poll Mode Response’ command. The format of time is determined by ATU
value.
Execute
AT+SMFPENDTIME?<CR>
AT+SMFPENDTIME=<UTC time>
Response
<UTC time><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default
01-01-2000/00:00:00
Range
01-01-2000/00:00:00 - 02-07-2136/06:28:15
7.15.5 AT+SMFPPERIOD or AT+SFP
Description
Get/Set Metering Fast Poll Mode Period. This value will be used in ‘Get Profile
Response’ command.
Execute
AT+SMFPPERIOD?<CR>
AT+SMFPPERIOD=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default
00
Range
00 - FF
7.15.6 AT+SMENDTIME or AT+SET
Description
Get/Set Metering End Time. This value will be used in ‘Get Profile Response’
command. The format of time is determined by ATU value.
Execute
AT+SMENDTIME?<CR>
AT+SMENDTIME=<UTC time>
Response
<UTC time><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default
01-01-2000/00:00:00
Range
01-01-2000/00:00:00 - 02-07-2136/06:28:15
7.15.7 AT+MSGETLAST or AT+MGL
Description
Send ‘Get Last Message’ command(Messaging cluster) to destination node.
(client-side command)
Execute
AT+DEST=<address>,<endpoint><CR>
AT+MSGETLAST<CR>
Response
OK<CR> or ERROR<CR>