SENA ProBee-ZE20S-SEME User Manual

Page 83

Advertising
background image

ProBee-ZE20S-SExx User Guide Rev 1.8

83

Execute

AT+EPID?<CR>

AT+EPID=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

0000000000000000

Range

0000000000000000 – FFFFFFFFFFFFFFFF

7.4.4

AT+GROUPID or AT+GI

Description

Get/Set the 16-bit Group ID. It is used for multicast data reception.

Execute

AT+GROUPID?<CR>

AT+GROUPID=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

0000

Range

0000 – FFFF

7.4.5

AT+POWER or AT+PW

Description

Get/Set the TX power at which the RF module transmits conducted power.

Execute

AT+POWER?<CR>

AT+POWER=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

8

Range

-43 – 8

7.4.6

AT+STACK or AT+ZS

Description

Get/Set the ZigBee stack profile value. This value must be set the same on all

devices that should join the same network. (0: Network specific, 1: ZigBee, 2:

ZigBee Pro). Do NOT change default value if you want to use for Smart Energy

node.

Execute

AT+STACK?<CR>

AT+STACK=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

2

Range

0 – 2

7.4.7

AT+NODENAME or AT+NN

Description

Get/Set the node name. It can be used to make a clear distinction role or

functionality of local node from others.

Execute

AT+NODENAME?<CR>

AT+NODENAME=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>