ProBee-ZE20S-SExx User Guide Rev 1.8

57

NETWORK KEY: FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF

LINK KEY TABLE

#|IEEE_ADDRESS |TYPE|AUTH|KEY

*|000195AABBCC0000|LINK|NO |41618FC0C83B0E14A589954B16E31466

1/6 ENTRIES USED

OK

# IEEE_ADDRESS changed to

# long address of Trust Center

5.4.5

ProBeeSEME End-device Configuration

Hardware configuration for the end-device is as follows:

Set the HOST switch to UART

Connect a serial cable between a host computer and the end-device

The AT commands for the ProBeeSEME end-device are as follows:

(Same as ProBeeSEID end-device)

#Screen of ProBeeSEME(end-device)

AT+NODETYPE=3

OK

AT+PANID=7772

OK

AT+LONGADDR

000195AABBCC0002

OK

ATZ

OK

Channel:14, PanID:7772

FAILED TO JOIN(AD)

# Failed to join with security error(AD)

AT+KEYTABLE

# Get Pre-configured Link Key

NETWORK KEY: FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF

LINK KEY TABLE

#|IEEE_ADDRESS |TYPE|AUTH|KEY

*|0000000000000000|LINK|NO |41618FC0C83B0E14A589954B16E31466

1/6 ENTRIES USED

OK