ProBee-ZE20S-SExx User Guide Rev 1.8

80

Response

List of the S-register

and description

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

7.2.5

ATZ

Description

Reset the node.

Execute

ATZ<CR>

Response

OK<CR>

7.2.6

AT&F

Description

Factory reset.

Execute

AT&F<CR>

Response

OK<CR>

7.2.7

ATU

Description

Get/Set UTC time format type for input/output.

(0: 32-bit hexadecimal ranging 0x00000000 ~ 0xFFFFFFFF,

1: MM-DD-YYYY/hh:mm:ss,

2: DD-MM-YYYY/hh:mm:ss,

3: YYYY-MM-DD/hh:mm:ss).

Execute

ATU?<CR>

ATU=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR> or ERROR<CR>

Default

1

Range

0 - 3

7.3

Node Specific Information

7.3.1

AT+LONGADDR or AT+LA

Description

Get the 64-bit IEEE address. (EUI address, long address) The IEEE address is a

unique device address assigned during manufacturing. This address is unique to

each physical device.

Execute

AT+LONGADDR?<CR>

Response

<IEEE address><CR>

OK<CR>

7.3.2

AT+SHORTADDR or AT+SA

Description

Get the 16-bit Node ID. (network address, short address) The node ID of “0000”

is reserved for the coordinator. All other devices receive a randomly generated

address from the coordinator or router device that allows the join. This value can

change if an address conflict is detected where two devices are found to have the