End-point No.1: ProfileID-0x0109, DeviceID-0x0501

Server-side cluster: 0x0000 (Basic)

Client-side cluster: 0x000A (Time)

Server-side cluster: 0x0702 (Simple Metering)

Client-side cluster: 0x0703 (Messaging)

Client-side cluster: 0x0800 (Key establishment)

Server-side cluster: 0x0800 (Key establishment)

OK

5.4.2

Install Code Configuration

Each device can set Install Code optionally for enhanced Smart Energy security. Install Code is used to

generate Pre-configured link key of joining node. Please refer to the section 3.3 Setting up Install Code

for detail.

Example) Set Install Code to ProBeeSEID(end-device)

#Screen of ProBeeSEID(end-device)

AT+INSTALLCODE

# Get current Install Code

INSTALL CODE: FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF # Now empty

OK

AT+INSTALLCODE=1122334455667788

# Set Install Code

OK

# Install code must be

# 6/8/12/16 byte hexadecimal

AT+INSTALLCODE

INSTALL CODE: 1122334455667788

# Successfully changed

OK

Example) Set Install Code to ProBeeSEME(end-device)

#Screen of ProBeeSEME(end-device)

AT+INSTALLCODE

# Get current Install Code

INSTALL CODE: FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF # Now empty

OK

AT+INSTALLCODE=1122334455667788

# Set Install Code

OK

# Install code must be

# 6/8/12/16 byte hexadecimal

AT+INSTALLCODE