‘FAILED TO JOIN(AD)’ means that ProBeeSEME node failed to join the network because Trust

Center(coordinator) had no Pre-configured link key of ProBeeSEME and denied to join. To fix it, Trust

Center(coordinator) node must add Pre-configured link key of end-device.

The AT commands for setting Pre-configured link key for Key Table of Trust Center(coordinator) is as

follows:

#Screen of ProBeeSESI(coordinator)

AT+KEYTABLE=1,000195AABBCC0002,41618FC0C83B0E14A589954B16E31466

OK

# Add Pre-configured Link Key of end-device(0001950000000003)

# to No.1 Key Table entry in coordinator

AT+KEYTABLE

NETWORK KEY: FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF

LINK KEY TABLE

#|IEEE_ADDRESS |TYPE|AUTH|KEY

0|000195AABBCC0001|LINK|NO |41618FC0C83B0E14A589954B16E31466

1|000195AABBCC0002|LINK|NO |41618FC0C83B0E14A589954B16E31466

2/6 ENTRIES USED

OK

Then, you can join successfully.

#Screen of ProBeeSEME(end-device)

Channel:14, PanID:7772

# Do not put any error message

# Successfully joined

AT+KEYTABLE

NETWORK KEY: FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF

LINK KEY TABLE

#|IEEE_ADDRESS |TYPE|AUTH|KEY

*|000195AABBCC0000|LINK|NO |41618FC0C83B0E14A589954B16E31466

1/6 ENTRIES USED

OK

# IEEE_ADDRESS changed to

# long address of Trust Center