SENA ProBee-ZE20S-SEME User Manual

Page 64

Advertising
background image

ProBee-ZE20S-SExx User Guide Rev 1.8

64

Then ProBeeSEME node receives following message:

#Screen of ProBeeSEME(end-device)

+0000|SE_DISPLAY_MESSAGE|11335577|01|0200|Test Message|08-22-2013/15:08:30

5.4.8

Showing Attribute Information

Each Smart Energy node has its own attributes. User can see their information by running the AT

command as below:

Example) Show attributes of ProBeeSESI node

#Screen of ProBeeSESI(coordinator)

AT+ATTR<CR>

# Show attributes of current device

clus|attr|data(clusterName)

0000|0000|01 (Basic)

0000|0001|00 (Basic)

0000|0002|00 (Basic)

0000|0003|00 (Basic)

0000|0007|00 (Basic)

0000|0011|00 (Basic)

0000|0012|01 (Basic)

0000|0013|00 (Basic)

0000|0014|00 (Basic)

0003|0000|0000 (Identify)

0701|0000|client-side (Demand Response and Load Control)

0701|0001|client-side (Demand Response and Load Control)

0701|0002|client-side (Demand Response and Load Control)

0701|0003|client-side (Demand Response and Load Control)

0800|0000|client-side (Key establishment)

0800|0000|0000 (Key establishment)

OK

# Response

# clus: cluster id

# attr: attribute id

# data: stored data