SENA ProBee-ZE20S-SEME User Manual
Page 96
ProBee-ZE20S-SExx User Guide Rev 1.8
96
Default
0000
Range
0000 – FFFF
7.13.9 AT+MSDISPLAY or AT+MDI
Description
Send ‘Display Message’ command(Messaging cluster) to destination node.
(server-side command)
Execute
AT+DEST=<address>,<endpoint><CR>
AT+MSDISPLAY=<data>?<CR>
Response
OK<CR> or ERROR<CR>
7.13.10 AT+MSCANCEL or AT+MCA
Description
Send ‘Cancel Message’ command(Messaging cluster) to destination node.
(server-side command)
Execute
AT+DEST=<address>,<endpoint><CR>
AT+MSCANCEL?<CR>
Response
OK<CR> or ERROR<CR>
7.13.11 AT+DLLIST or AT+DLT
Description
Show DRLC Event List.
Execute
AT+DLLIST?<CR>
Response
event ID|clss|gr|dura|cr|cool(sp)|heat(sp)|av|du|ct|start time
..
OK<CR>
7.13.12 AT+DLSTARTTIME or AT+DST
Description
Get/Set DRLC Start Time. This value will be used in AT+DLSET. The format of
time is determined by ATU value.
Execute
AT+DLSTARTTIME?<CR>
AT+DLSTARTTIME=<UTC time>
Response
<UTC time><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default
01-01-2000/00:00:00
Range
01-01-2000/00:00:00 - 02-07-2136/06:28:15
7.13.13 AT+DLSET or AT+DLS
Description
Add/Modify DRLC Event.
Execute
AT+DLLIST=<event ID>,<device class>,<utility enrolment group>,<duration in
minutes>,<criticality
level>,<cooling
offset>,<cooling
set
point>,<heating
offset>,<heating set point>,<average load adjustment percentage>,<duty
cycle>,<event control><CR>