ProBee-ZE20S-SExx User Guide Rev 1.8

47

illumination and analog input is as follows:

Illumination(Lux) = Volt(mV) * 0.25(Lux/mV)

Note: The LED On/Off switch (SW20) should be placed to LED_OFF.

5.3.10 Terminal Block

The development board has a terminal block for external analog inputs. Figure 5-2 shows the layout of

the terminal block. To use external analog inputs instead of the variable resistors, temperature sensor or

light sensor, the ADC_0 (SW4), ADC_1 (SW5), ADC_2 (SW6) or ADC_3 (SW7) should be placed on

EXT_0, EXT_1, EXT_2, or EXT_3.

Figure 5-2 Terminal Block for External Anlalog Inputs

Note: The LED On/Off switch (SW20) should be placed to LED_OFF.

5.4

Configuration Example: 1 Coordinator and 2 End-Devices

Here is an example assuming different system configurations. This example can be described as follows:

Setting CBKE Data Token and Install Code of all ZE20S modules for Smart Energy security.

One ZE20S module acts as a ProBeeSESI coordinator and it is connected to a host computer via

USB cable.

One ZE20S module acts as a ProBeeSEID end device and it receives control commands from

the others.

One ZE20S module acts as a ProBeeSEME end device and it receives control commands from

the others.