SENA ProBee-ZE20S-SEME User Manual

Page 48

Advertising
background image

ProBee-ZE20S-SExx User Guide Rev 1.8

48

Figure 5-3 Example: 1 Coordinator and 2 End-Devices

5.4.1

CBKE Data Token Configuration

Hardware configuration for all devices is as follows:

Set the HOST switch to UART

Update ProBeeSESI firmware to a node for coordinator (See Chapter 2.3.3)

Update ProBeeSEID firmware to a node for end-device (See Chapter 2.3.3)

Update ProBeeSEME firmware to a node for end-device (See Chapter 2.3.3)

Each device should have CBKE Data Token before it acts as Smart Energy node for Smart Energy

security. In this example, each device uses test certificate derived from its long address. These

certificates in the example cannot be used for your devices. You should get certificate for your own

devices. Please refer to the section 3.2 Configuring CBKE Data Token for detail.

Test certificates for devices in this example are as follows:

Certificate#1 for ProBeeSESI(coordinator)

Long address: 0x000195aabbcc0000

CA Public Key: 0200fde8a7f3d1084224962a4e7c54e69ac3f04da6b8

Device Implicit Cert:

030505d6aed0c401c4003ae871fa2af4697fb89b5a8d000195aabbcc0000544553545345434101091aabba

abbccddeef

Device Private Key: 00f156135beca22bc66388b26730e038525144be6c

Certificate#2 for ProBeeSEID(end-device)

Long address: 0x000195aabbcc0001

CA Public Key: 0200fde8a7f3d1084224962a4e7c54e69ac3f04da6b8

Device Implicit Cert:

0306a4e44deed93d6ce13ff81a6916e2c3473b1d0efe000195aabbcc0001544553545345434101091aabba

abbccddeef

Device Private Key: 037ee06d90cadf5d399f0358260f70607e4f584f14

Advertising