8.1.3

S13

Description

Get/Set the command responses mode.

Execute

ATS13?<CR>

ATS13=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR>

Default

1

Range

0 - 1

8.1.4

S14

Description

Get/Set the LED mode. It causes the LED operation if the device is ZE20S set

GPIO15, 16 to specific functionality.

0: LEDs are always OFF regardless of configuration or status.

1: LEDs are OFF when the node is under sleep status.

2: LEDs always operate by the case.

Execute

ATS14?<CR>

ATS14=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR>

Default

1

Range

0 - 2

8.2

Network Settings

8.2.1

S22

Description

Get/Set the timeout to permit joining. It determines the time in seconds that the device

will allow other devices to join to it when it starts network but an end-device cannot

perform it. If set to 255, the device will always permit joining.

Execute

ATS22?<CR>

ATS22=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR>

Default

255

Range

0 - 255

8.2.2

S23

Description

Get/Set the power boost mode of the module. If enabled, boost mode improves

sensitivity and increases output power, improving the link margin and range.

Execute

ATS23?<CR>

ATS23=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR>