SENA ProBee-ZE20S-SEME User Manual

Page 90

Advertising
background image

ProBee-ZE20S-SExx User Guide Rev 1.8

90

7.11 Firmware Upload and Help

7.11.1 AT+BOOTLOAD or AT+BL

Description

Start bootloader to upload firmware. (blank: local, 1: passthru)

The device leaves the AT command line and enters the bootloader menu for

uploading new ProBee firmware. There’s no restrict to use local upload but a

sleepy end-device cannot upload to remote node over the air. The current UART

should be set 115200bps, 8 data bits, no parity, 1 stop bit and none flow control.

Execute

AT+BOOTLOAD<CR>

AT+BOOTLOAD=<number>,<IEEE><CR>

Response

Bootloader menu

Serial upload complete

Please start .ebl upload image ...<CR> or

Start cloning ...<CR>

Bootloader menu

Bootload Complete!

7.11.2 AT+HELP or AT+HP

Description

Show all the available commands

Execute

AT+HELP<CR>

Response

Available AT Commands

OK<CR>

7.12 Smart Energy Commands

7.12.1 AT+ATTR or AT+AR

Description

Show all attributes of local node.

Execute

AT+ATTR?<CR>

AT+ATTR=<clusterID><CR>

Response

clus|attr|data(cluster name)

<clusterID>|<attributeID>|<data>(<clusterName>)

OK<CR>

7.12.2 AT+INFO or AT+IF

Description

Show Smart Energy device information

Execute

AT+INFO?<CR>

Response

Security Level: <security level>, Security Profile: SE

End-point count: <endpointCount>

End-point No.<endpoint>: ProfileID-<profileID>, DeviceID-<deviceID>

Client-side cluster: <clusterID>(<clusterName>)

Server-side cluster: <clusterID>(<clusterName>)

...

Advertising