SENA ProBee-ZE20S-SEME User Manual

Page 81

Advertising
background image

ProBee-ZE20S-SExx User Guide Rev 1.8

81

same address or a device leaves the network and later joins.

Execute

AT+SHORTADDR?<CR>

Response

<node ID><CR>

OK<CR>

7.3.3

AT+ADDRDISCOVERY or AT+AD

Description Get the corresponding address of a node whose long or short address is known.

Execute

AT+ADDRDISCOVERY=<IEEE><CR> AT+ADDRDISCOVERY=<nodeID><CR>

Response

<node ID><CR>

OK<CR>

<IEEE address><CR>

OK<CR>

7.3.4

AT+OPCH or AT+OC

Description

Get the operating channel number used for transmitting and receiving between

RF modules. Uses 802.15.4 channel numbers. A value of “0” means the device

has not joined a PAN and is not operating on any channel.

Execute

AT+OPCH?<CR>

Response

<value><CR>

OK<CR>

7.3.5

AT+OPPANID or AT+OI

Description

Get the operating 16-bit PAN ID. If PAN ID is set specific value not 0s, operating

PAN ID will equal designated PAN ID. A value of “FFFF” means the device is not

joined a network.

Execute

AT+OPPANID?<CR>

Response

<value><CR>

OK<CR>

7.3.6

AT+OPEPID or AT+OE

Description

Get the operating 64-bit extended PAN ID. A value of “FFFFFFFFFFFFFFFF”

means the device is not joined a network.

Execute

AT+OPEPID?<CR>

Response

<value><CR>

OK<CR>

7.3.7

AT+VERSION or AT+VR

Description

Get firmware version of the module. The firmware version returns a form of

“SExxvx.x”.

Execute

AT+VERSION?<CR>

Response

<value><CR>

Advertising