Af-60 lp™ micro drive programming guide – GE Industrial Solutions AF-60 LP Micro Drive User Manual

Page 20

Advertising
background image

Change-over point is automatically calculated based on motor size.

1-61 High Speed Load Compensation

Range:

Function:

Use this parameter to obtain optimum load compensation when running at high speed.

100 %

*

[0 - 199 %]

Enter percentage to compensate in relation to load when motor runs at high speed.

Change-over point is automatically calculated based on motor size.

1-62 Slip Compensation

Range:

Function:

100 %

*

[-400 - 399 %]

Compensation for load dependent motor slip.

Slip compensation is calculated automatically based on rated motor speed, n

M,N

. Example: if par. 1-62 is set to 100%

and the 4 pole 1800 RPM motor has an actual nameplate RPM of 1750 RPM, then 50 RPM is added to the output

frequency by the drive.

NB!

This function is only active when par. 1-00, Configuration Mode, is set to Speed Open Loop [0], and when par. 1-01,

Motor Control Principle, is set to Advanced Vector Control [1].

1-63 Slip Compensation Time

Range:

Function:

0.10 s [0.05 - 5.00 s]

Enter slip compensation reaction speed. A high value results in slow reaction whereas a low value results in quick

reaction.

If low-frequency resonance problems arise, use longer time setting.

4.2.5. 1-7* Start Adjustments

Considering the need for various start functions in different applications, it is possible to select a number of functions in this parameter group.

1-71 Start Delay

Range:

Function:

The start delay defines the time to pass from a start command is given until the motor starts accelerating.

Setting start delay to 0.0 sec. disables Start Function, [1-72], when start command is given.

0.0 s

*

[0.0 - 10.0 s]

Enter the time delay required before commencing acceleration.

Par. 1-72 Start Function is active during Start delay time .

1-72 Start Function

Option:

Function:

[0]

DC Hold/Delay Time

Motor is energized with DC holding current (par. 2-00) during start delay time.

AF-60 LP™ Micro Drive Programming Guide

19

4