Af-60 lp™ micro drive programming guide – GE Industrial Solutions AF-60 LP Micro Drive User Manual

Page 67

Advertising
background image

13-

10 Com

parator Operan

d

*[0] Di

sable

d

[1] R

e

fe

renc

e

[2] Fee

dback

[3] Moto

rSp

eed

[4] Moto

rCurr

e

n

t

[6] MotorPo

wer

[7] MotorV

olta

ge

[8] D

C

LinkVoltage

[12] A

n

alog

In

pu

t53

[13] A

n

alog

In

pu

t60

[18] P

u

ls

eIn

put

3

3

[20] Al

arm

N

u

m

b

e

r

[30] Cou

n

terA

[31] Co

un

terB

13-

11 Com

parator Operato

r

[0] Le

ss Than

*[

1

] A

p

pr

o

xim

ate

ly

eq

ua

ls

[2] Greater

Than

13-

12 Compa

ra

to

r Va

lu

e

-9999 - 9

999 *

0.0

13-2* Ti

mers

13-

20 LC Con

troller T

im

e

r

0.0 - 3600

s * 0.0 s

13-4* Logic

Rule

s

13-

40 Logic Rule B

oolean 1

See p

a

r. 13-01

* [0] Fa

lse

[30] - [32] LC Tim

e

-out

0-2

13-

41 Logic Rule Operator 1

*[0] Di

sable

d

[1] And

[2] Or

[3] And not

[4] Or

no

t

[5] No

t and

[6] No

t or

[7] No

t and not

[8] No

t or not

13-

42 Logic Rule B

oolean 2

See par

. 13-40

13-

43 Logic Rule Operator 2

See

p

a

r. 13-41 * [

0

] Di

sabl

ed

13-

44 Logic Rule B

oolean 3

See par

. 13-40

13

-5

* S

tat

es

13-

51 LC Con

troller Event

See par

. 13-40

13-

52 LC Con

troller Action

*[0] Di

sable

d

[1

] N

o

A

c

ti

o

n

[2

] S

e

le

ct

S

e

tu

p

1

[3

] S

e

le

ct

S

e

tu

p

2

[1

0-17] SelectPresetR

ef

0-7

[1

8]

S

e

le

ct Acce

l/De

cel 1.

[1

9]

S

e

le

ct Acce

l/De

cel 2.

[2

2

] R

u

n

[2

3] Ru

nR

ev

erse

[2

4

] S

to

p

[2

5

] Qs

to

p

[2

6

] D

C

st

o

p

[2

7

] C

o

a

st

[2

8

] F

re

e

ze

O

u

tp

ut

[2

9] Star

tT

im

er0

[3

0] Star

tT

im

er1

[3

1] Star

tT

im

er2

[3

2]

Set Digita

l Outp

ut

A Low

[3

3]

Set Digita

l Outp

ut

B Low

[3

8]

Set Digita

l Outp

ut

A High

[3

9]

Set Digita

l Outp

ut

B High

[6

0]

Re

setCo

unterA

[6

1]

Re

setCo

unterB

14-

**

Spec

ia

l F

u

nc

ti

o

n

s

14-

0

* C

a

rri

er

F

requ

e

n

cy

14-01 Motor

Noise

(C

ar

rie

r Fr

equency)

[0

] 2

kH

z

*[1] 4

kH

z

[2

] 8

kH

z

[4

] 1

6

k

H

z

14-03 Overmod

u

lation

[0

] O

ff

*[1] On

14

-1

* M

a

ins

monit

ori

n

g

14-12 Fun

c

tion

at

ma

in

s

imbalan

c

e

*[0] T

ri

p

[1

] W

a

rn

in

g

[2

] D

is

a

b

le

d

14

-2

* T

ri

p

R

e

se

t

14-20 Reset

Mode

*[

0] Ma

nua

l rese

t

[1

-9

] A

u

to

R

e

se

t 1

-9

[1

0]

AutoReset

10

[1

1]

AutoReset

15

[1

2]

AutoReset

20

[1

3]

In

finite

auto

rese

t

14-21 Automa

ti

c

Resta

rt

Time

0 - 600 s * 10 s

14-22 Restore

Factory

Setti

n

g

s

*[0] N

o

rm

al

Oper

ati

on

[2

] R

e

st

or

e F

a

ct

o

ry

S

e

tt

ing

s

14-26 Action

At

Dri

ve

Fault

*[0] T

ri

p

[1

] W

a

rn

in

g

14

-4* Energy S

a

vings

14-41 Energy Savings Minimum Magn

etisation

40 - 75 % * 66 %

15

-*

* Dri

ve I

n

for

mat

ion

15

-0* O

p

erati

ng Dat

a

15-00 Opera

ti

n

g

Da

ys

15-01 Runnin

g

H

o

urs

15-02 kWh Coun

te

r

15-03 P

o

w

e

r

Ups

15-04 Over

Temp

s

15-05 Over

Volts

15-06 Reset

kWh

Coun

ter

*[0] Do not

reset

[1

] R

e

se

t c

o

u

n

te

r

15-07

Reset Runn

in

g H

o

urs Counter

*[0] Do not

reset

[1

] R

e

se

t c

o

u

n

te

r

15

-3*

F

a

ul

t

L

o

g

15-30 Fa

ul

t

Log

: Error Cod

e

15

-4*

Dri

v

e Id

en

ti

fi

ca

ti

on

15-40 GE

Drive

Type

15-41 P

o

w

e

r

Section

15-42 Vo

lt

a

g

e

15-43 S

o

ftware

V

e

rsion

15-46

Frequen

c

y

Convert

er Order.

N

o

15-48

K

e

ypad Id No

15-51 Frequen

c

y

Convert

er

Serial

No

16-

**

Dat

a

Reado

u

ts

16

-0*

Ge

ne

ra

l Sta

tus

16-00 Con

trol

Word

0 - 0XFFFF

16-01 Ref

e

ren

c

e

[Unit]

-4

999 - 4

999

16-02 Ref

eren

c

e

%

-2

00.0 - 200.0

%

16-03 S

ta

tus

Wo

rd

0 - 0XFFFF

16-05 Main

Actu

a

l

Va

lu

e

[%

]

-2

00.0 - 200.0

%

16-09 Custom

R

e

ad

out

Dep

. o

n

p

a

r. 0-31, 0-32

an

d

4-14

16-1

* M

o

tor St

at

us

1

6

-10 Power

[kW]

1

6

-11 Power

[hp

]

1

6

-12 Moto

r Voltag

e

[V]

16-13 Fr

equency

[Hz]

16-14 Motor C

u

rre

nt [A]

16-15 Fr

equency

[%]

1

6

-18 Moto

r Th

ermal [%]

16-3*

Dri

ve Status

1

6

-30 DC Link Vo

lt

ag

e

1

6

-34 H

e

a

tsink Temp.

1

6

-35 Inverter Th

ermal

1

6

-36 Drive

Nom

in

al c

u

rre

nt

1

6

-37 Drive M

aximum Current

16-38 Logi

c Controlle

r State

16-5

* Re

f. / Fee

db.

1

6

-50 Extern

al Reference

1

6

-51 Pu

lse Reference

1

6

-52 Feedba

ck [Unit]

16-6*

Input

s / O

u

tp

uts

1

6

-60 Digital Inp

ut

18,19,27,

33

0

- 1111

1

6

-61 Digital Inp

ut

29

0 -

1

1

6

-62 Ana

lo

g Input 53 (volt)

1

6

-63 Ana

lo

g Input 53 (current)

1

6

-64 Ana

lo

g Input 60

1

6

-65 Ana

lo

g Ou

tp

ut

42 [mA]

1

6

-68 Pulse Input [Hz

]

1

6

-71 Re

lay Ou

tp

ut

[bin]

1

6

-72 Counter A

1

6

-73 Counter B

16-

8

* F

iel

dbus

/ GE Dr

ive

Port

1

6

-86 GE Dri

v

e Port

REF 1

0

x8000 - 0x

7F

FFF

16-9*

Dia

gnosis

Re

adou

ts

1

6

-90 Alarm

Word

0

-

0XFFFFFF

FF

16-92 Warning Wor

d

0

-

0XFFFFFF

FF

1

6

-94 Ext. Status

Word

0

-

0XFFFFFF

FF

AF-60 LP™ Micro Drive Programming Guide

66

5

Advertising