2-20 Release Brake Current

Range:

Function:

0.00 A

*

[0.00 - 100 A]

Select motor current at which mechanical brake releases.

If start delay time has passed, and motor current is below Release brake current, frequency converter

trips.

2-22 Activating Mechanical Brake

Range:

Function:

If the motor is stopped using ramp, the mechanical brake is activated when motor speed is less than Active Brake

Speed.

Motor is ramped down to stop in the following situations:

A start command is removed (stand by)

A stop command is activated

Quick-stop is activated (Q-stop ramp is used)

0 Hz

*

[0 - 400 Hz]

Select motor speed at which mechanical brake activates when ramping down.

Mechanical brake automatically activates if frequency converter trips or reports an alarm.

AF-60 LP™ Micro Drive Programming Guide