GE Industrial Solutions 6KCV300WPD User Manual

Page 138

Advertising
background image

Description

It performs a logical not-operation of the data read by input port

a.

This block treats values read by input port

a

as boolean variable, so that:

l

value equal zero FALSE (0)

.

value different from zero TRUE

As the value shown in output port o is a boolean value, it will be 0 or 1.

a

0

F

T

T

F

Input ports

name type

alternative type function

a

int

Data a

Output ports

name type

alternative

function

0

int

negative data a

Parameters

No parameters

128