GE Industrial Solutions 6KCV300WPD User Manual

Page 148

Advertising
background image

Parameters

name

offset

int

int

int

alternative type function

8192

Offset to be summed to the parameter identifiers

0

Identifier of the DRIVE parameter that will be

found in slot 0 of the communication structure.

0

Identifier of the

parameter that will be

found in slot 1 of the communication structure.

0

Identifier of the

parameter

will be

found in slot 2 of the communication structure.

0

Identifier of the

parameter that will be

found in slot 3 of the communication structure.

0

Identifier of the

parameter that will be

found in slot 4 of the communication structure.

The DGFC board communicates to the DRIVE through a device called DPRAM. This device allows the
DGFC

card to write or read from the parameters of the

and consequently to condition its functioning.

In DPRAM there are various communication structures with different functioning modes.

The

structure piloted by the ODS block carries out a writing operation of DGFC to the

parameters. The maximum number of parameters to be controlled by this structure is 5. The writing of

the parameters occurs at the end of each regulation cycle.

The communication structure is composed of five slots. Inside each

slot

3 data are contained:

l

Identifier of DRIVE parameters

l

TYPE

of DRIVE parameters

l

VALUE

Values to be written in the parameter specified by

During the transition of DGFC from

the communication structure is configured:

l

DGFC copies

parameters in the

field of the respective

slots.

l

DGFC requires the DRIVE to carry out the configuration of the communication structure.

l

The

analyses the parameter identifiers in the

field and if it finds them in compliance with

each other, it writes the type of the required parameter in the TYPE field. The TYPE field will be used
during the communication to perform the automatic conversion of data.

If any parameter identifier does not comply with the others, the whole communication structure will be
disabled and the output port in RUN will contain value
After the configuration of the communication structure and until

DGFC

does not move into the RUN status,

the value 0 will be written

in the VALUE

field.

When DGFC is in the RUN status, the value read by input ports

is copied in the

VALUE

field of the

corresponding communication structure and, at the end of each regulation cycle in the associated parameter of

The

offset

parameter is summed to

parameters, this permits to refit the parameter identifiers.

Advertising