Chapter 3 Operation

95

[Operation of Rotary Actuator]

1)

2)

Home = 0°

Home sensor

1) The actuator rotates in CCW (counterclockwise) direction from the view point of the load

side. The velocity is either 20deg/s or 5deg/s. (It depends on the setting of each actuator.)

2) At the home sensor input, the actuator is turned in the reverse direction and stopped at the

home position. The rotation angle is the value set by Parameter No.22 “Home return offset

level” after the detection of phase Z.

Caution: Make sure to refer to Section 8.2 [18] when a change to Parameter No.22

“Home Return Offset Level” is required.

[Operation of Actuator of Gripper Type]

1) If the HOME signal is turned ON, the actuator moves toward the mechanical end at the

home return speed (20mm/s).

2) The actuator is turned at the mechanical end and stopped at the home position. The

rotation angle is the value set by parameter No.22 “Home return offset level” after the

detection of phase Z.

Caution: Make sure to refer to Section 8.2 [18] when a change to Parameter No.22

“Home Return Offset Level” is required.

1)

2)

Advertising