2 ladder sequence – IAI America SCON-CA User Manual

Page 288

Advertising
background image

Chapter 10

Appendix

278

10.3.2 Ladder Sequence

[1] Servo ON (Emergency Stop) Circuit

1) It is presumed that the emergency stop release circuit installed in the operation box

possesses the self-retaining circuit as shown in “2.1.3 [3] Emergency Stop Circuit”. When it

comes to the emergency stop release condition, “Servo-on” signal from PLC to SCON

turns ON.

2) Then if the emergency stop release state continues, the operation ready complete signal

(sent from SCON to PLC) is turned on to go on the “Emergency stop release” lamp, which

indicates that the actuator can be operated.

[2] Operation and Stop Circuit

000

002

IN0

IN0

OUT14

OUT0

IN14

EMGRST

Emergency Stop Cancel

Servo ON

Emergency Stop

Cancel Display

EMGRST

Emergency

Stop Cancel

SV

SON

EMRSTL

Operation

Preparation End

This circuit may only consist of SV. However, to go

off the emergency stop release lamp immediately at

external emergency stop, it also includes EMGRST

because EMGRST not only goes on the lamp but also

performs the emergency stop processing of other circuits.

005

012

IN1

OUT1

OUT1

IN13

IN2

IN0

OUT11

OUT1

OUT2

START

RC Start

RC Start Display

STARTL

RC Start Display

STARTL

RC Start Display

PEND

Point

Positioning

Completion

STOP

RC Stop

EMGRST

Emergency

stop cancel

Stop Command

HOME

STARTL

STOPL

Home Return

Step number:

It shows the number of steps on PLC.

(Interlock)

Prohibits start during home return.

a007 b012 b044

a071 a076 a085

a091 a097 a103

a109 a115 a121

a127 a133

RC Stop Display

a035

Once the servo ON the controller turns ON, PEND

turns ON to conduct a positioning to the current position.

Therefore, it is used to judge whether operation is

available (to confirm READY condition ON controller).

Cross Reference:

It shows the steps using the contact

of this signal.