Chapter 1 Specifications Check

30

1.5.3 Regenerative Unit : REU-1, REU-2 (Option)

This is a unit that converts the regenerative current to heat when the motor decelerates.

[Specification]

Item

Specification

Body Size

W34mm × H195mm × D126mm

Body Weight

0.9kg

Internal Regenerative Resistor

235� 80W

REU-1

(Note)

Controller Connection Cable (Model Code CB-ST-REU010) 1m

Accessories

REU-2

Controller Connection Cable (Model Code CB-SC-REU010) 1m

Note : REU-1 is used as the second and following units when more than one regeneration unit is used.

[Appearance]

(Note) Refer to 2.3.6 Connection of Regenerative Unit for the number of connectable units.