Chapter 8 I/O Parameter

232

When a change is required to the home position, do a calculation following the formula below and

input the calculated value to the parameter.

1) Setting for Single Slider Type:

Parameter setting value = Initial parameter at delivery from factory (Parameter No.150) + Desired

offset amount

2) Setting on Slider 2 for Double Slider Type (Refer to 1) for Slider 1):

Parameter setting value = [Initial parameter at delivery from factory (Parameter No.150) + Stroke

(value indicated when purchased) + Slider length (value shown in

catalog) + Min. distance between Sliders (value shown in catalog)] –

Desired offset amount

(Note 4) For the spurious absolute type actuator, No.22: Home-return Offset Value and No.139:

Home Preset Value are invalid.

For the actuators other than the spurious absolute type, this parameter is invalid.

[118] Light Error Alarm Output Select (Parameter No.151)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

151

Light Error Alarm Output

Select

FSTP

0: Battery Voltage Drop

Warning Output

1: Output of battery

voltage drop warning

or message-level

alarm

0

It can be selected if an output is to be made when a message-level alarm is generated as well

as when the battery voltage drop error is occurred for the output condition of BALM signal.

(Note) For Pulse Train Mode, by setting this parameter to “1”, OUT12 becomes the ALML (Light

Error Alarm) signal and outputs when a message-level alarm is generated.

Desired

offset amount

Initial

parameter at

delivery from

factory

Desired

Home

Position

Desired offset amount

Initial parameter

at delivery from

factory

Desired Home Position

Initial parameter at delivery from factory + Stroke + Slider length +

Min. distance between Sliders

Slider 2

Slider 1