3.1 Basic Operation

3.1.1 Basic Operation Methods

There are two types, Positioner Mode and Pulse Train Control Mode, for the operation. Select

the suitable one considering the system function.

There are various types of actuators including slider, rod, rotary and gripper types. The same

operation control method is applicable unless particular descriptions are contained in this

manual.

(1) Positioner Mode

1) Set target positions (coordinate values), velocities, accelerations, and decelerations by the

required number of positioning points in the position table by using a teaching tool such as

PC software.

2) Enter the binary data of position numbers subject to positioning on the PLC and turn ON

the start signal.

3) The actuator is placed at the proper coordinate value according to the positioning

information in the specified position number.

4) If the positioning is completed, the binary data of the position number is output. The

completion signal is also output.

The above procedure describes the basic operation method in the positioner mode.

Completion

Signal

Signal

Signal

Edit Position

Table of

controller

Actuator

Controller

Teaching Pendant or

PC software

Position Number

+

Start Signal

PLC

Enter a data including

position, velocity,

acceleration or

deceleration, etc.

No.

[G]

0

1

100.00

0.30

0.30

2

200.00

0.30

0.30

100.00
200.00

Acceleration Deceleration

Velocity

[mm]

[mm/s]

[G]

Position