IAI America SCON-CA User Manual

Page 184

Advertising
background image

Chapter 3 Operation

174

[4] Error monitor during torque limiting

No.

Name

Symbol

Unit

Input

Range

Initial

Value

59

Error monitor during torque limiting

FSTP

0 to 1

0

You can select whether to enable or disable the function to monitor deviation while torque is

being limited (the TL signal is ON).

By enabling this function, you can have the controller output an error while torque is being

limited, if a deviation equal to or exceeding the value set by the applicable parameter.

0: Disable

1: Enable

[5] Deviation Counter Clear Input

No.

Name

Symbol

Unit

Input

Range

Initial

Value

60

Deviation Counter Clear Input

FPIO

0 to 1

0

You can select whether to enable or disable the function to clear the generated deviation while

torque is being limited (the TL signal is ON).

Disable this function in conditions where torque must be limited (pressing is not performed).

0: Disable

1: Enable

[6]� Torque limit command input

No.

Name

Symbol

Unit

Input

Range

Initial

Value

61

Torque limit command input

FPIO

0 to 1

0

Torque control of the motor with the value set in Parameter No.57 “Torque Control Value” can

be performed with PIO (TL Signal ON) from the host system. In this parameter, a choice can

be made from using (disable) TL Signal (Torque Limiting Signal) and not using (enable) the

signal.

0: Disable

1: Enable

[7]� Pulse count direction

No.

Name

Symbol

Unit

Input

Range

Initial

Value

62

Pulse count direction

FPIO

0 to 1

Set

individually

You can set the direction in which the motor turns according to command pulses.

Set the same value as that set in Parameter No.5 “Home-Return Direction” and the actuator

moves in positive direction if the command pulse is input in positive direction.

0: Forward rotation

1: Reverse rotation

[8] Compulsory Stop Input

No.

Name

Symbol

Unit

Input

Range

Initial

Value

67

Compulsory Stop Input

FPIO

0 to 1

0

Compulsory stop of the actuator can be performed with PIO (CSTP Signal ON) from the host

system. In this parameter, a choice can be made from using (disable) CSTP Signal

(Compulsory Stop Input Signal) and not using (enable) the signal.

0: Disable

1: Enable

Advertising