Chapter 3 Operation

109

� �

Caution: (1) If the actuator reaches the software limit corresponding to the stroke end in the pitch

feed operation, the actuator stops at the position and positioning complete signal

PEND is turned ON.

(2) Note that, in pitch feed just after pressing operation (to be in the pressing state), the

start position is not the stop position at the completion of pressing but the

coordinate value entered in “Position” of the pressing position data. The movement

to the base point is added to the first pitch feed.

(3) If the position number for pitch feed is started (CSTR ON) during normal positioning,

the actuator moves to the position of the coordinate resulting from adding the pitch

feed distance to the target coordinate of the positioning. Repeating the start of pitch

feed several times allows the pitch feed distance to be added to the target position

by the number of repeats. Do not use the pitch feed function in such a way, because

the PLC cannot confirm the complete position.

(4) Note that, if pitch feed is started (CSTR ON) repeatedly during pause, the actuator

moves continuously by the distance based on the number of starts. In such a case,

cancel the remaining moving distance by turning reset signal RES to ON in the

pause state or take interlock so that the start signal is not turned ON during pause.

(5) At software limit (stroke end) in pitch feed, the actuator is decelerated to be stopped

and positioning complete output PEND is output.

(6) MOVE turns ON at the same time as PEND turns OFF, and turns OFF once PEND

turns ON or the movement command output completes. Accordingly, with a large

positioning width being set, MOVE may be turned OFF while the actuator is moved.

(7) Pressing is enabled by using the pitch feed function. However, do not make control

of changing to pitch feed on the way of normal positioning (before PEND turning

ON). Pressing is interrupted by using the pitch feed function as soon as start signal

CSTR is turned ON. The PLC cannot manage the position of the actuator any more.

Approach

Pressing

Current stop position

Base point of pitch

Movement to base point of pitch feed +

pitch feed distance

Second and following

pitch feed

= setting value

Return to base point and first pitch

Pressing operation

Second and following

pitch feed

= setting value

Pitch feed in reverse pressing

Pitch feed in same

direction as pressing

Advertising