Chapter 3 Operation

112

� �

Caution: (1) The speed during pressing operation is set in Parameter No.34. Check the

10.4 List of Specifications of Connectable Actuators for the pressing

operation speed.

Do not set any value larger than the value in the list. If the speed set in the

position table is equal to or less than the pressing speed, the pressing is

performed at the setup speed.

(2) The approach start position of pressing should be located at or before the

pressing start position (coordinate 100mm or less in the above example) If

not, the moving direction varies depending on the start position to be

dangerous.

For example, if the pressing operation is conducted from a coordinate value

above the pressing complete position (above 150mm), it will become the

tension operation from the current point to the pressing complete position.

Please note that it cannot be the pressing operation to the point of 150mm

after the positioning at the point of 100mm.


(3) The work is pressed after the pressing is completed. The work may moves

backward or forward. If the actuator is moved backward before the

approach position, alarm code 0DC “Pressing Motion Range Over Error”

occurs to stop the actuator. In movement of the work in the pressing

direction, PEND is turned OFF if the load current becomes lower than the

current limit (pressing (%)). Miss-pressing occurs when the actuator moves

by the pressing moving distance set in “Positioning width”. Completed

Position No. PM1 to PM** keep turned on until the next movement

command is made even if the work piece gets moved and pushed

backward or goes further forward once they are turned on at the pressing

operation complete.

(4) Do not make control of changing to pressing on the way of normal

positioning (before PEND turning ON). Depending on the position at which

start signal CSTR is turned ON, the pressing is performed improperly. Then

the PLC cannot manage the position of the actuator.

(5) Pressing operation cannot be performed with the rotary actuator. If the

index mode is selected for the rotary actuator of multi-rotation specification,

pressing operation cannot be set. The positioning complete signal PEND is

turned ON when the actuator reaches the positioning width.

(6) If the actuator gets pressed to the work during the approach operation, 0DC

“Pressing Motion Range Over Error” would be issued.

(7) If the actuator is RCS2-RA13R (Ultra-High Thrust Type), there is a limit in

the duration and duty of continuous pressing. Use of the product above this

limit may cause a failure occurred due to the motor heat generation.

[Refer to 10.4.2 Specifications and Limitations in Pressing Operation of

RCS2-RA13R]

Pressing start position

100mm

Pressing end position

100 + 50 = 150mm

CSTR

Pressing operation

CSTR

Approach operation

CSTR: Start position

CSTR

Pressing operation

Tension operation